Friedrich Hazardgard
SH20L30-B · Serial LFKR17744

Hazardous-location room air conditioner; nameplate indicates 230/208 V AC, 60 Hz, 1-phase; 19,800/19,500 BTU/hr; R22.
Technical specifications, installed equipment register and supporting manufacturer certification documents.
ITS-03 · Exterior ventilation grilleTranscribed from historical ICO Inspection Consultants Asiapacific data plate. Values have not been independently reverified.
Equipment summaries with actual ITS-03 photographs and local certificate PDF links. Equipment identification and functional status are subject to verification. Documents not yet uploaded are labelled accordingly.
SH20L30-B · Serial LFKR17744

Hazardous-location room air conditioner; nameplate indicates 230/208 V AC, 60 Hz, 1-phase; 19,800/19,500 BTU/hr; R22.
96HD sensor · Display ID 7821

Industrial gas detector shown in the previous cabin fire-and-gas installation. Historical marking: II 2G, EEx d IIC T6.
DB5 · 2005 label

Audible alarm/siren associated with the cabin fire-and-gas system. Historical marking: II 1G EEx ia IIC T4.
Model 55000-200 · Ionisation type
17–28 V DC smoke detector. Historical LPCB product listing is available; standard model 55000-200 has not been established as an Ex/IS variant.
Serial 994870 · 2005


Explosion-protected enclosure associated with the cabin distribution/main-switch arrangement. Plate: II 2GD EEx d IIB; IP56.
FONDISONZO enclosure · exact assembly model unconfirmed

Fire alarm control panel, zone indicators and related fire/gas interfaces. Original wiring drawing FA-XX-001 is referenced in historical records.
Ceiling-mounted light fittings · Model / quantity to verify

Interior ceiling light fittings shown in the original cabin records. Include luminaire type, wattage, voltage, Ex marking and installed quantity after nameplate confirmation.
Equipment identification and performance to verify

Cabin mechanical exhaust provision. Record manufacturer, model, Ex marking, airflow rating, voltage, installation location and shutdown/interlock logic during site verification.
Equipment identification and performance to verify

Cabin fresh-air inlet or supply fan. Record manufacturer, model, rated airflow, Ex marking and connection to the cabin safety/ventilation controls. Airflow direction to be verified on site.
CEAG control switches · Exact part numbers to verify

Switches for cabin lighting and ventilation, visible in historical installation photographs. Record each switch type, circuit function and individual hazardous-area marking.
Built-in laboratory cabin furniture · Dimensions / quantities to measure

Existing worktops, under-bench cabinets and storage units shown in cabin interior reference photographs. Document layout, material, mounting condition, dimensions and available work area.
Control model and software revision to confirm

Controls cabin power-up and original safety interlock sequence. Functional testing, alarm/trip response and final configuration remain to be verified.
OTB122 enclosure · Exact assembly function to verify

Explosion-protected cable termination enclosure at the labelled 240 VAC incoming supply. Nameplate displays BAS98ATEX3083X and IP66; the certificate and assembly suitability are not independently verified.
Photographs depict equipment supplied for ITS-03; they do not establish current functional or hazardous-area compliance. Four certificate/document links retain the exact filenames previously uploaded. Remaining documents are marked pending.
This page is a technical reference for preliminary customer/vendor evaluation, not an offshore release certificate.
Unavailable; replacement certification assessment being explored.
Current certification status unverified. Historical plate does not establish present lifting suitability.
Equipment reinstalled; PLC power-up and integrated functional tests planned.
Manufacturer approval documents being compiled into the cabin technical file.